AP/AP - AP/CH - CH/CH - pear type

Slings stay cable with spelter sockets, AP-AP open-open, AP-CH open-closed, CH-CH closed-closed and type pear socket

AP/AP

AP/CH

CH/CH

Pear type

Rope Ø  Code Breaking strength Galv/OSS A B D C E F
  AP-AP / AP-CH
CH-CH
Pear type S9/S10
S11
AR
S9/S10/S11
S12 Galv./OSS Rope Ø
AP-AP / AP-CH
CH-CH
Pear type          
mm kN kN kN kN mm Code Code mm mm mm mm mm mm
10 TF AP-CH-10 FA PERA 10 75,4 84,4 96,3 109 11 TF AP-CH-11 FA PERA 11 20,6 45 20,6 17,5 24 52
12 TF AP-CH-12 FA PERA 12 100,5 122 139 152 13 TF AP-CH-13 FA PERA 13 15 45 25,4 23 30 59
14 TF AP-CH-14 FA PERA 14 149,0 165 191 202 15 TF AP-CH-15 FA PERA 15 32 63 30 26 36 65
16 TF AP-CH-16 FA PERA 16 195,0 216 249         32 63 30 25 36 65
18 TF AP-CH-18 FA PERA 18 242,8 273 316 322 19 TF AP-CH-19 FA PERA 19 38 76 35 32 42 78
20 TF AP-CH-20 FA PERA 20 306,0 338 390         45 89 41 38 50 90
22 TF AP-CH-22 FA PERA 22 370,0 408 471 430 22     45 89 41 38 50 90
24 TF AP-CH-24 FA PERA 24 440,6 486 561 512 24     51 101 51 45 57 103
26 TF AP-CH-26 FA PERA 26 472,0 571 654 601 26     51 101 51 45 57 103
28 TF AP-CH-28 FA PERA 28 547,0 662 759 697 28     57 114 57 51 65 116
30 TF AP-CH-30 FA PERA 30 628,0 760 871 799 30     57 114 57 51 65 116
32 TF AP-CH-32 FA PERA 32 715,0 864 991 909 32     63 127 63 57 71 130
34 TF AP-CH-34 FA PERA 34 807,0 954 1120 1030 34     63 127 63 57 71 130
36 TF AP-CH-36 FA PERA 36 904,0 1070 1250 1150 36     63 127 63 57 80 155
38 TF AP-CH-38 FA PERA 38 1007,0 1190 1400 1280 38     76 162 70 63 80 155
40 TF AP-CH-40 FA PERA 40 1120,0 1320 1550 1420 40     76 165 76 70 84 171
44 TF AP-CH-44 FA PERA 44 1350,0 1570 1940 1720 44     89 178 89 76 95 198
48 TF AP-CH-48 FA PERA 48 1610,0 1870 2300 2040 48     89 178 89 76 95 198
50 TF AP-CH-50 FA PERA 50 1745,0 2030 2500 2220 50     101 228 95 82 96 224
52 TF AP-CH-52 FA PERA 52 1890,0 2190 2700 2590 54 TF AP-CH-54 FA PERA 54 101 228 95 83 111 224
60 TF AP-CH-60 FA PERA 60       3210 60     113 254 108 92 125 248
66 TF AP-CH-66 FA PERA 66       3780 66     127 273 121 102 140 270

Safety factor used can be change from 3 to 5 conforming to design static calculation or standard specification.
Metal and resin socketing based on our Internal procedure based on EN 13411.
Resin socketing application approved by RINA third body organization.
The length L is on request.